广告招募

当前位置:欧亚贸易网 > 技术中心 > 所有分类

ARCH电源应用资料

2023年06月22日 11:22:52      来源:西安浩南电子科技有限公司 >> 进入该公司展台      阅读量:36

分享:

[ Application Note ]   

 

  AC-DC Application Note  
 
          AC Input Line Connection :
  The pin of AC line (L), ac neutral (N),the third wire safety ground (FG) should be retained from the AC power outlet to the power supply input terminals without accidental interchange. (Figure 1.1)
  (Figure 1.1)
  The FG pin should be connected to the equipment where power supply is placed as thickershorter to protect electric shock or noise interference. (Figure 1.2)
  (Figure 1.2)
 
 
          Fuse :
  To add a fuse at the input terminals of the power supply to provide safetyprotection. We suggest using a 1. slow blow fuse for our AC-DC Converters including AHC, APC, ATC, ANCASC series. (Figure 2.1)
  (Figure 2.1)
 
 
          Seriesparallel operation :
  I. Series operation
Most power converters can be operated in series if they have overload limitation by either constant current or constant power circuits. To protect each output from the reverse voltage applied by the other unit in the event of load short circuits, reverse biased diodes are used as shown in Figure 3.1
  (Figure 3.1)
  II. Parallel operation
This is only recommended with power converters specifically designed for parallel connection. In the parallel redundant scheme illustrated in Figure 3.2 one of the power converters could be replaced by a battery followed by a DC-DC converter to provide a no-break power system in the event of main supply failure.
  (Figure 3.2)
 
 
          Reduce the output ripplenoise :
  Please be aware the length of screw should not be longer than 3 mm while you mounting/ adopting our power supply on your end application, in case screw break through Mylar or PCB Board result in short circuit.
  (Figure 4.1)
 
 
          Screws for Switching Power Supply (AQS & AQF Series) :
  Please be aware the length of screw should not be longer than 3 mm while you mounting/ adopting our power supply on your end application, in case screw break through Mylar or PCB Board result in short circuit.
 
     
  DC-DC Application Note  
 
          Connection for standard use :
  Cin: External capacitor on the input side
Co: External capacitor on the output side
 
 
 
          Reverse input voltage protection :
  Avoid the reverse input voltage because it will damage the power supply. Installing an external diode can protect the converter from the reverse input voltage.
 
 
 
          Seriesparallel operation :
  I. Series operation
Most power converters can be operated in series if they have overload limitation by either constant current or constant power circuits. To protect each output from the reverse voltage applied by the other unit in the event of load short circuits, reverse biased diodes are used as shown in Figure 3.1
  (Figure 3.1)
  II. Parallel operation
This is only recommended with power converters specifically designed for parallel connection. In the parallel redundant scheme illustrated in Figure 3.2 one of the power converters could be replaced by a battery followed by a DC-DC converter to provide a no-break power system in the event of main supply failure.
  (Figure 3.2)
 
 
          Remote On/ Off Control Pin :
  Positive logic remote on/ off turns the module on during a logic high voltage on the remote on/ off pin,off during a logic voltage low. In order to turn module on or off, the use must supply a switch to control the voltage between the on / off terminalthe –Vin terminal.
 
  AC-DC Application Note:                           DC-DC Application Note:

版权与免责声明:
1.凡本网注明"来源:欧亚贸易网"的所有作品,版权均属于兴旺宝装备总站,转载请必须注明兴旺宝装备总站。违反者本网将追究相关法律责任。
2.企业发布的公司新闻、技术文章、资料下载等内容,如涉及侵权、违规遭投诉的,一律由发布企业自行承担责任,本网有权删除内容并追溯责任。
3.本网转载并注明自其它来源的作品,目的在于传递更多信息,并不代表本网赞同其观点或证实其内容的真实性,不承担此类作品侵权行为的直接责任及连带责任。其他媒体、网站或个人从本网转载时,必须保留本网注明的作品来源,并自负版权等法律责任。 4.如涉及作品内容、版权等问题,请在作品发表之日起一周内与本网联系。

[{"ID":"233949","Title":"无杆气缸的拆卸步骤和维修方法","OrderField":"Prev"},{"ID":"233951","Title":"自动打包机的操作流程","OrderField":"Next"}] $item.OrderField