您好,欢迎来到欧亚贸易网!请 |免费注册

产品展厅本站服务收藏该商铺

CHANGSHA LANGSHUO TECHNOLOGY CO LTD

免费会员
手机逛
CHANGSHA LANGSHUO TECHNOLOGY CO LTD
当前位置:CHANGSHA LANGSHUO TECHNOLOGY CO LTD>>Flammability Test Chamber>> LR-JCY-3 ASTM D2843 Smoke Density Tester For Building Materials

LR-JCY-3 ASTM D2843 Smoke Density Tester For Building Materials

产品二维码
参  考  价:面议
具体成交价以合同协议为准
  • 产品型号:
  • 品牌:
  • 产品类别:硬度计
  • 所在地:
  • 信息完整度:
  • 样本:
  • 更新时间:2025-07-14 16:09:02
  • 浏览次数:5
收藏
举报

联系我时,请告知来自 欧亚贸易网

CHANGSHA LANGSHUO TECHNOLOGY CO LTD

其他

  • 经营模式:其他
  • 商铺产品:911条
  • 所在地区:
  • 注册时间:2025-07-13
  • 最近登录:2025-07-13
  • 联系人:
产品简介

1

详情介绍
  1. 1. Scope of application:

Touch-screen computer dual control smoke density tester for building materials was developed according to the technical conditions stipulated in GB/ t8627-2007 “test methods for smoke density of burning or decomposition of building materials”, which is applicable to the measurement of static smoke production from burning of building materials, products and other materials.

  1. Product features
  2. Dual control mode, can control the operation on the touch screen, can also be controlled on the computer, the operation mode can be arbitrarily switched!
  3. A device can operate several computers at the same time, several computers can be online at the same time, and LAN sharing can be realized!
  4. The main and auxiliary burners can rotate automatically and locate accurately.
  5. Independently developed the control program, which can meet all kinds of operations, records, real-time curves and results calculation in the test.
  6. Relevant technical parameters
  7. For the maximum smoke density (MSD) and smoke density grade (SDR) of the specimen: 0-99% continuously measurable and automatically calculated;
  8. Calibration error with standard filter shall not be more than 3%;Each device is equipped with three standard filters, which are representative of the data of light source calibration
  9. Working pressure of Bunsen burner (210 + 5) KPa;
  10. The Bunsen burner applied flame to the sample for 4min;
  11. Burning lamp: in the Bunsen burner and a length of 260 mm, the nozzle diameter of 0.13 mm, with smoke box into a 45 ° Angle;
  12. Photoelectric system: the light source is a bulb with 15W power and 6V working voltage;
  13. Exhaust air system: this machine is equipped with powerful exhaust fan, which can discharge exhaust gas out of the outdoor after the test;
  14. Smoke density measurement range: 0~99%;
  15. Smoke density measurement accuracy: ±3%;
  16. Receiver: silicon photocell, light transmittance 0% is no light, light transmittance 99% is no shade completely through;
  17. Working pressure of main burner: 276KPa (adjustable);
  18. Automatic timing, automatic ignition, automatic smoke extraction;Optical flux can be divided into stages for linear correction test data

A more accurate;

  1. Touch the screen:
  2. Size: 5 “effective display size 11cm long and 6.28cm wide;
  3. Resolution: 800*480
  4. Communication interface RS232, 3.3v CMOS or TTL, serial port mode
  5. Storage capacity :1G
  6. Pure hardware FPGA drive display, “zero” startup time, power can run
  7. M3+FPGA architecture is adopted. M3 is responsible for instruction analysis, and FPGA focuses on TFT display
  8. The main controller adopts a low-energy processor and automatically enters the energy-saving mode
  9. Gas source: 95% propane gas, or gas of the same purity (customer provided);
  10. Length * width * height 740 *500* height 900 (mm)

 

  1. Working conditions:
  2. Ambient temperature: 0 ℃ and 40 ℃;
  3. Relative humidity: less than 85%
  4. Power supply voltage and power: 220V + / – 10%, 50HZ, 100W;
  5. Gas pressure: 0-0.3mpa (adjustable);
  6. Environment and test requirements: avoid direct irradiation or reflection of strong light on the instrument during operation;After the test for 90min, the gas source should be turned off to cool the instrument for 15min.
  7. Ambient air flow: there is no forced air flow phenomenon when working;
  8. The instrument should be placed in the fume hood for testing;
  9. Instrument structure:

Divided into smoke box and control two parts;

Smoke box: on the left and right sides of the smoke box panel, there are power switch, safety sign switch (back light switch), gas regulator, in addition to the control exhaust fan switch (fan switch).

Vi. Design standard: GB/ t8627-2007 smoke density test method for combustion or decomposition of building materials

Standard: GB/T8627 ASTM D2843